Turnkey Solutions

PFMEA and control plan: steps, AP vs RPN and example

What a PFMEA is, its 7 steps, action priority vs RPN, how the process flow diagram, PFMEA and control plan link, a worked example, the Control Plan 1st edition and the audit findings to avoid.

FG
Filip Gergely
20 min read
Quality team reviewing a PFMEA and control plan in a manufacturing plant

A PFMEA, or process failure mode and effects analysis, is a structured risk analysis of a manufacturing process. For each process step the team lists how it can fail, what the failure does to the customer and why it happens, then decides which controls prevent or detect it. The control plan turns those controls into shop-floor checks.

Both documents are frequent audit topics. In IATF 16949 audits, clause 8.5.1.1, the control plan, caused 3.04% of all major nonconformities and clause 8.3.5.2, manufacturing process design output, caused 3.75% (IATF top ten major nonconformities, October 2026). This guide covers the 7 PFMEA steps, action priority versus RPN, the link from the process flow diagram to the control plan, a worked example and the findings auditors write most often.

Key takeaways
  • The PFMEA says why and what to control. The control plan says how, how often and how many.
  • The AIAG and VDA handbook runs a PFMEA in 7 steps and ranks risk with action priority, high, medium or low, instead of the RPN.
  • Use the same step numbers and special characteristics in the process flow diagram, the PFMEA and the control plan.
  • The AIAG Control Plan 1st edition of 2024 is a standalone manual and adds Safe Launch to the control plan phases.
72h
From your request to the right GQ interim expert on site Source: GQ interim 2026 brochure

What is PFMEA in manufacturing?

In manufacturing, a process FMEA is the team’s analysis of everything that can go wrong in a process before it goes wrong on the line. It covers each step of the process flow, from receiving to shipping, rates each failure for severity, occurrence and detection, and defines actions for the highest risks. It is a living document that changes with the process.

Most automotive suppliers follow the AIAG and VDA FMEA handbook, first edition issued in June 2019 (VDA QMC). It harmonized the American AIAG and the German VDA methods and covers design FMEA, process FMEA and FMEA for monitoring and system response. Ford requires its own FMEA handbook and also accepts the AIAG and VDA format (Ford Specifics for PPAP, June 2026).

What is the difference between PFMEA and FMEA?

FMEA is the general method. A process FMEA applies it to a process: machines, people, methods, materials and the environment of each step. A DFMEA applies it to the product design. The two are linked: severity ratings and special characteristics flow from the DFMEA into the PFMEA. Our DFMEA vs PFMEA comparison explains where one ends and the other starts.

What are the 7 steps of PFMEA?

The AIAG and VDA handbook splits every FMEA into seven steps: planning and preparation, structure analysis, function analysis, failure analysis, risk analysis, optimization and results documentation (Quality-One summary of the AIAG VDA FMEA). Steps 2 to 4 build the failure chain, step 5 rates it, and step 6 is where actions are decided.

  1. Planning and preparation
    Define the scope, the team, the timing and the tools with the 5T method: intent, timing, team, task and tool. Take the process flow diagram and the lessons learned from similar parts.
  2. Structure analysis
    Break the process into process items, process steps and process work elements such as the machine, the operator, the material and the environment. A block diagram or a structure tree shows the boundaries.
  3. Function analysis
    Describe what each step and work element must achieve, with the product and process characteristics it creates, for example “mold ruler to length 300 mm plus or minus 0.5 mm”.
  4. Failure analysis
    Build the failure chain for each function: failure effect on the customer, failure mode at the step, failure cause in the work element.
  5. Risk analysis
    Record the current prevention and detection controls, rate severity, occurrence and detection from 1 to 10 with the handbook tables, and read the action priority from the AP table.
  6. Optimization
    Assign actions, owners and dates for high and medium action priority, implement them and re-rate occurrence and detection once they are proven.
  7. Results documentation
    Report the results to management and the customer, and carry the agreed controls into the control plan and the work instructions.

What is the difference between action priority and RPN?

The risk priority number, or RPN, multiplies severity, occurrence and detection, each rated 1 to 10. Action priority, or AP, replaces the multiplication with a table that assigns high, medium or low to each of the 1,000 combinations and looks at severity first, then occurrence, then detection (Quality-One).

The RPN looks precise but hides very different risks. Only 120 of the numbers from 1 to 1,000 can be an RPN, and the value 120 alone can come from 24 different combinations, for example severity 2 with occurrence 6 and detection 10, or severity 8 with occurrence 5 and detection 3 (Sadia et al., arXiv 2018). A fixed RPN threshold treats both the same. Action priority would flag the second one first, because the severity is high.

RPN compared with action priority
AspectRPN (AIAG 4th edition and older)Action priority (AIAG and VDA 2019)
CalculationSeverity multiplied by occurrence multiplied by detectionLookup table for every combination
ResultA number from 1 to 1,000High, medium or low
WeightingAll three ratings count equallySeverity first, then occurrence, then detection
What the team must doAct above a chosen thresholdHigh: must act or justify; medium: should act; low: could act
Typical problemThresholds that ignore high severity with low occurrenceCustomer-specific AP tables to follow

Check what your customer requires. Stellantis asks suppliers to use its own action priority tables whatever FMEA standard they follow (Stellantis CSR, 2025), and General Motors works with risk priority levels based on the severity, occurrence and detection tables (GM CSR, October 2025).

What is a control plan?

A control plan is a document that describes how the product characteristics and the process characteristics of each step are controlled. For every line it lists the characteristic, the specification, the measurement technique, the sample size and frequency, the control method and the reaction plan. It is one of the core tools of APQP and part of the PPAP submission.

What changed with the AIAG Control Plan 1st edition?

Until 2024 the control plan was a chapter of the AIAG APQP and Control Plan manual. Since March 1, 2024 it has its own reference manual (Quality Magazine, August 2024). The AIAG Control Plan 1st edition clarifies requirements and the link to APQP, adds Safe Launch to the control plan phases and gives examples for highly automated processes and control plan software.

Customers moved fast. General Motors required the new manual from September 1, 2024 (AIAG, March 2024), and Ford asks for control plans to the latest AIAG Control Plan manual since December 31, 2024 (Ford Specifics for PPAP).

Three phases of a control plan

A prototype control plan covers the measurements and tests during prototype builds. A pre-launch control plan, including Safe Launch, adds extra checks and containment at the start of production. The production control plan covers series production and is updated for the life of the part.

What is the difference between a PFMEA and a control plan?

The PFMEA is an analysis and the control plan is an instruction. The analysis finds the risks of each process step and decides which controls are needed. The control plan describes how those controls are carried out every shift: what is measured, with which gauge, how often, by whom and what happens when a result is out of specification.

PFMEA compared with a control plan
AspectPFMEAControl plan
Main questionHow can this process step fail, and why?How do we check this step, how often, and what if it fails?
Main contentFailure chains, ratings, prevention and detection controls, actionsCharacteristics, specifications, measurement technique, sample size and frequency, control method, reaction plan
Main usersCross-functional team: quality, process engineering, production, designOperators, inspectors, shift leaders and auditors
Risk ratingSeverity, occurrence, detection and action priorityNone, but the controls follow the analyzed risk
RelationshipExplains why each control existsDescribes how each control is carried out
Need your FMEA and control plan ready before an audit?
Tell us the product, the customer and the audit date. We come back with quality experts who have built these documents before.
Find your expert

How do the process flow diagram, PFMEA and control plan link together?

The three documents describe one process in a fixed order. The process flow diagram lists every step, including transport, storage, inspection and rework. The process FMEA analyzes each of those steps. The control plan takes the controls the analysis relies on and makes them daily work. So the flow diagram comes first, then the risk analysis, then the control plan.

Ford spells out the chain: characteristic traceability is required from the DFMEA through the PFMEA to the control plan and to the process instructions, and every PFMEA and control plan needs approval by Ford product development engineering (Ford Specifics for PPAP, June 2026). The same logic applies to alternative controls: when a plant uses a backup control, it should be defined in the process flow, the PFMEA, the control plan and the standardized work (IATF 16949 FAQs, June 2026).

Keep special characteristics identical

Special characteristics must carry the same symbol and number on the drawing, in the process flow diagram, in the PFMEA and in the control plan. Stellantis, for example, requires severity 10 in the PFMEA for any characteristic classified as safety. A symbol missing in one document is a common audit finding.

What does a control plan contain?

Customer formats differ, but most control plans follow the AIAG layout with the same columns. The table shows each column with a simple injection molded part as the example: a transparent plastic ruler, 300 mm long. The values are illustrative.

Typical control plan columns with a molded ruler as the example
ColumnWhat it holdsRuler example
Process stepNumber and name from the process flow diagramStep 20, injection molding
Machine or toolEquipment used at this stepInjection molding machine 3, mold 1
CharacteristicProduct or process characteristic, with its numberProduct: ruler length. Process: shot size
Special characteristic classCustomer symbol, if anyNone for this ruler
SpecificationTarget and toleranceLength 300 mm plus or minus 0.5 mm; shot size set per process sheet
Measurement techniqueGauge or methodCaliper; machine monitoring
Sample size and frequencyHow many parts and how often5 pieces every hour; shot size every cycle
Control methodHow the result is recorded and controlledSPC chart; parameter alarm limits
Reaction planWhat to do when a result is out of specificationStop, quarantine parts since the last good check, inform the shift leader
Quality engineer and production supervisor checking a control plan next to an injection molding machine
The control plan is used where the work happens: at the machine, by the people who run it.

PFMEA and control plan example: a molded ruler

Follow one failure chain from the risk analysis into the control plan. For the customer, the length of the ruler matters: a ruler that is too short is defective. The analysis for step 20, injection molding, records the chain below. The example is a teaching case, not a GQ interim project.

One PFMEA line for the molding step
PFMEA fieldEntry
Process stepStep 20, injection molding
FunctionMold the ruler to length 300 mm plus or minus 0.5 mm
Failure effectRuler too short: the customer rejects the batch
Failure modeRuler length below the lower limit
Failure causeShot size or holding pressure set wrong after a mold change
Prevention controlProcess sheet with locked parameters, alarm limits on shot size
Detection controlLength measured with a caliper, 5 pieces every hour
RiskSeverity, occurrence and detection rated with the handbook tables; action priority read from the table

The prevention control works on the process and the detection control on the product. The control plan therefore gets two lines for step 20: shot size as a process characteristic with machine monitoring and alarm limits, and length as a product characteristic with 5 pieces every hour on an SPC chart. Both lines carry the same reaction plan. If the action priority came out high, the team would add a stronger control, for example automatic length checking on every part, update the detection rating and write the new check into the control plan.

How do you build a control plan from the PFMEA?

Build the control plan line by line from the risk analysis, never from an old template. Each process step comes from the flow diagram, each characteristic and control from the FMEA, and each sample size from the risk. Eight steps take a team from a finished analysis to a released control plan.

  1. Start from the process flow diagram
    Copy every process step with its number and name, including receiving inspection, rework, storage and shipping.
  2. Take the characteristics from the PFMEA
    For each step, list the product and process characteristics linked to failure modes and causes in the FMEA. Mark special characteristics with the customer’s symbols.
  3. Add specifications
    Take target and tolerance from the drawing, the customer specification or the process parameter sheet.
  4. Transfer the controls
    Each prevention control becomes a process check, each detection control an inspection with a measurement technique. Use the same wording.
  5. Set sample size and frequency
    Base them on risk. GM asks for sample sizes and frequencies based on risk, occurrence of failure modes and volume. High action priority items and special characteristics need tighter checks, SPC, automatic inspection or poka-yoke.
  6. Write a specific reaction plan
    For every line, describe what the operator does when a result is out of specification: stop, contain, inform and correct.
  7. Check the measurement systems
    Every gauge in the control plan needs valid calibration and, for special characteristics, a measurement system analysis.
  8. Review it on the shop floor
    Walk the line with operators and shift leaders, check that every control is done as written, then release the document and train the team.
Control the process, not only the product

Checking process characteristics prevents defects; checking product characteristics only finds them. If the relationship between shot size, holding pressure and ruler length is understood and controlled, short rulers are not made at all.

Free e-book

The interim management guide for manufacturing companies

When to bring in an interim quality expert for a launch, an audit or a customer escalation, and how to brief one.

  • When an interim manager pays off
  • How to write a mandate
  • The first 30 days, week by week

How does action priority affect the control plan?

Action priority decides where the control plan gets stricter. For a high AP the team must lower the risk or document why the current controls are enough; the result shows in the control plan as a better prevention control, a larger sample, a higher frequency or automatic detection. Severity itself does not move to the control plan; the controls and their frequency do.

The link also works backwards. When the shop floor shows that a control does not work, for example when defects still reach the customer, the occurrence and detection ratings must be updated. A detection rating that assumes a check catches every defect is only valid if the control plan really requires that check, and the records show it was done.

What should a reaction plan include?

A reaction plan tells the operator exactly what to do when a check fails, so nobody has to improvise on a night shift. “Inform the supervisor” alone is a weak plan. A good one covers five actions, and for error-proofing devices GM expects a reaction plan with containment in the control plan (GM CSR, October 2025).

  • Stop: stop the machine or the line, or stop shipping parts from this step.
  • Contain: quarantine all parts made since the last good check, including parts already in later steps or in the warehouse.
  • Inform: tell the shift leader and quality, with a defined escalation if the problem is not solved within the shift.
  • Correct and verify: adjust the process, check the first parts again and release production only after a good result.
  • Record: write down what happened, so recurring problems go into problem solving and the FMEA.

Problems that come back or reach the customer need a formal root cause analysis, for example with the 8D method or structured problem solving.

Operator measuring a molded plastic part with a digital caliper at an inspection station
A detection control only works if the gauge, the sample size and the frequency in the control plan are followed every shift.

What are the most common audit findings for PFMEA and control plans?

IATF 16949 clause 8.5.1.1 requires control plans for the pre-launch and production phases that reflect the PFMEA and the process flow, with minimum content in Annex A. Auditors check consistency between the documents and evidence from the line. These are the findings that come up most often:

  • Step numbers differ between the process flow diagram, the PFMEA and the control plan.
  • Controls differ: a control used in production is missing from the control plan, or is worded differently.
  • Special characteristics differ: symbols on the drawing, in the FMEA and in the control plan do not match.
  • Reaction plans are vague: lines say “inform the supervisor” without stop, contain and correct.
  • Gauges are not valid: a measurement technique has no calibrated gauge or no measurement system analysis.
  • The plan is out of date: engineering changes, complaints and FMEA updates are not in the latest revision.
  • The shop floor does not follow it: check sheets and SPC charts do not show the checks at the stated frequency.

How often should a PFMEA and control plan be updated?

Update both documents whenever the process, the product, the customer requirements or the risk changes, and after every defect that reaches the customer. Many customers also ask for a fixed review: GM requires a PFMEA review of all manufacturing parts and processes at least once a year, supported by tools such as reverse PFMEA (GM CSR, October 2025).

A reverse PFMEA starts on the shop floor instead of in the meeting room. The team stands at each step, tries to create the failure modes, and checks whether the analysis lists them and whether the controls in the control plan catch them. New findings go back into both documents in the same revision.

How GQ interim helps

Risk analyses and control plans fall behind when a plant is busy with launches, complaints and audits. An experienced FMEA moderator or quality manager can run the 7-step workshops, align the flow diagram, PFMEA and control plan for a product family, prepare an IATF 16949 or customer audit and train your engineers to keep the documents current. See our FMEA consultant and interim quality manager pages.

72h
to first profiles
Quality experts for FMEA and control plans
FMEA moderation, control plans, APQP, PPAP and customer audits. The right expert is on site within 72 hours.
Find your expert
2,560+
GQ interim projects since 2015 (GQ interim project data, November 2026)
7,500+
Experts in our database (GQ interim 2026 brochure)
240+
Clients in Central and Eastern Europe (GQ interim 2026 brochure)
Are you a quality or production engineer?
Join 7,500+ experts in our database and get offers for interim projects in manufacturing across Europe.
See open projects

Conclusion

The process FMEA finds the risks, and the control plan makes sure the controls against them happen every shift. Run the analysis in the 7 steps, prioritize with action priority instead of RPN thresholds, keep the flow diagram, FMEA and control plan aligned step by step, and write reaction plans that tell people exactly what to do. Then both documents prevent defects instead of only satisfying an auditor.

Interested in our services?

Get a quality expert for your FMEA and control plan this week

Tell us the product, the customer and the deadline. We come back with experts who have done this before.

72h
From brief to expert on site

Frequently asked questions

What is the first step in FMEA?

In the AIAG and VDA method the first step is planning and preparation: define the scope, the team, the timing and the tools, and collect inputs such as the process flow diagram and lessons learned. Structure analysis follows as step 2.

What is RPN in the FMEA process?

The risk priority number is severity multiplied by occurrence multiplied by detection, each rated 1 to 10, so it ranges from 1 to 1,000. The AIAG and VDA handbook replaced it with action priority, which ranks every combination high, medium or low and weighs severity first.

Is PFMEA a Six Sigma tool?

PFMEA is used in Six Sigma projects, mostly in the analyze and improve phases of DMAIC, but it is older and broader than Six Sigma. In automotive it is one of the core tools of APQP and is required by IATF 16949.

What is the difference between DFMEA, PFMEA and the control plan?

A DFMEA analyzes how the product design can fail. A PFMEA analyzes how the manufacturing process can fail. The control plan describes how the process and product characteristics from both are checked in production.

Can you have a control plan without a PFMEA?

Formally you can write one, but under IATF 16949 it would not meet the requirement, because the control plan must reflect the PFMEA. Without the risk analysis nobody can explain why a check exists or how often it is needed.

Which comes first, the PFMEA or the control plan?

The process flow diagram comes first, then the PFMEA, then the control plan. In practice the team drafts the control plan while finishing the analysis, but every control plan line must trace back to a PFMEA line.

How do you set the sample size and frequency in a control plan?

Base them on the risk from the FMEA, the capability of the process, the volume and the customer requirements. Special characteristics and high action priority items need more frequent checks, SPC or automatic inspection; stable, capable processes can be checked less often.

How are MSA and SPC used in a control plan?

Measurement system analysis shows that the gauge named in the control plan measures well enough for the tolerance. Statistical process control is a common control method in the control plan for monitoring important characteristics with control charts.

Is there a standard control plan template?

Many customers prescribe their own format. Most templates follow the AIAG layout with the columns listed in this article. Annex A of IATF 16949 and the AIAG Control Plan manual describe the minimum content.

FG
Written by
Filip Gergely

Filip Gergely is the founder and CEO of GQsystems, a.s., the company behind the GQ interim brand. He founded it in 2011 in Nitra, Slovakia. GQ interim provides interim managers and engineers to manufacturing companies in Central Europe, mainly in the automotive industry, and has completed 1,550+ projects. You can follow him on LinkedIn: https://www.linkedin.com/in/filipgergely.